Table 2.
Acquisition capability of the developed data acquisition system
| Single-frame pixel number (in X and Y axes) with 4 kHz resonant scanner |
Largest pixel number (× 4 channels) | Maximum data size per frame (in megabytes) | Approximate frame rate (in frames per second) | |||||
|---|---|---|---|---|---|---|---|---|
| Fast X axis |
Slow Y axis | |||||||
| Sampling rate in mega samples per second (MSps) | ||||||||
| 20 MSps | 50 MSps | 70 MSps | 100 MSps | 125 MSps | ||||
| 2400 | 6224 | 8800 | 12,520 | 15,720 | 16,000 | 15,720 × 16,000×4 | 1918.9 | 0.49 |
| 2400 | 6224 | 8800 | 12,520 | 15,720 | 12,000 | 15,720 × 12,000×4 | 1439.2 | 0.64 |
| 2400 | 6224 | 8800 | 12,520 | 15,720 | 8000 | 15,720 × 8,000×4 | 959.47 | 0.96 |
| 2400 | 6224 | 8800 | 12,520 | 15,720 | 4000 | 15,720 × 4000×4 | 479.74 | 1.88 |
| 2400 | 6224 | 8800 | 12,520 | 15,720 | 1000 | 15,720 × 1000×4 | 119.93 | 7.87 |
| 2400 | 6224 | 8800 | 12,520 | 15,720 | 500 | 15,720 × 500×4 | 59.967 | 15.75 |
| 2400 | 6224 | 8800 | 12,520 | 15,720 | 250 | 15,720 × 250×4 | 29.984 | 31.5 |
| 2400 | 6224 | 8800 | 12,520 | 15,720 | 16 | 15,720 × 16×4 | 1.919 | 490 |
| 2400 | 6224 | 8800 | 12,520 | 15,720 | 8 | 15,720 × 8×4 | 0.959 | 980 |