Table 2.

Cardiac magnetic resonance imaging and angiography*

Parameters Mean values
Group A
 Right ventricular outflow dimension by magnetic resonance (mm) 19.3±1.2 (18-20)
 Right ventricular outflow dimension by angiography (mm) 21.1±1.2 (19-23)
 Right ventricular outflow dimension by balloon sizing (mm) 20.9±1.7 (19-24)
 Mean difference (angiography vs. balloon) (mm) 0.3±0.8 (−1-+1)
 Mean difference (magnetic resonance vs. balloon) (mm) 0±1.7 (−2-1)
 LPA stenosis or hypoplasia 1/7
Group B
 Pulmonary regurgitant fraction (%) 45.6±11.8 (26-64)
 Indexed right ventricular end-diastolic volume (ml) 167.26±25.9 (120-230)
 Right ventricular ejection fraction (%) 46.9±9.6 (27-65)
 Right ventricular outflow dimension by magnetic resonance (mm) 25.1±4.2 (19-32)
 Right ventricular outflow dimension by angiography (mm) 26.1±3.3 (20-32)
 Right ventricular outflow dimension by balloon sizing (mm) 28.0±3.3 (23-33)
 Mean difference (angiography vs. balloon) (mm) 1.9±2.4 (−8-+2)
 Mean difference (magnetic resonance vs. balloon) (mm) 2.8±2.9 (−10-+1)
 LPA stenosis or hypoplasia 4/22

*Values expressed in mean±SD (range). SD: Standard deviation, LPA: Left pulmonary artery