Table 2:

CT derived metrics and their values in the complete cohort, patients with normal/abnormal RV on echocardiograms and those with normal/elevated biomarkers. All values are presented as median (IQR)

Full Cohort RV Parameters on Echocardiogram Cardiac biomarkers
CT Measures, ml Normal Abnormal p value Normal Elevated p value
Distal blood volume 40.61 (36.01 – 45.11) 42.07 (37.22 – 46.33) 39.41 (34.77 – 43.55) <0.001 41.71 (37.20 – 45.92) 39.36 (34.38 – 43.74) <0.001
Distal venous blood volume 14.41 (11.91 – 16.47) 14.93 (12.73 – 17.18) 13.4 (11.09 – 15.52) <0.001 15.07 (12.78 – 17.15) 13.42 (10.95 – 14.45) <0.001
Distal arterial blood volume 26.14 (23.38 – 29.22) 26.47 (23.67 – 29.65) 25.67 (22.85 – 28.73) 0.02 26.52 (23.63 – 29.50) 25.63 (22.79 – 28.74) 0.013
RV:LV ratio on CT 1.2 (1.06 – 1.37) 1.11 (0.99 – 1.25) 1.32 (1.16–1.46) <0.001 1.14 (1.02 – 1.27) 1.3 (1.13 – 1.46) <0.001