TABLE 2. Single Predictor Models of Water Pb Detection and WLL ≥2 ppb.
Predictor | Outcome: Pb Detection, OR (95% CI) | Outcome: WLL ≥2 ppb, OR (95% CI) |
---|---|---|
House built 1986 or earlier | 5.18 (2.35-11.42)a | 2.88 (1.16-7.16)b |
House built pre-1964 (25th percentile) | 1.42 (0.65-3.09) | 0.41 (0.15-1.16) |
House built pre-1978 (median) | 2.22 (1.13-4.34)b | 1.25 (0.59-2.63) |
House built pre-1994 (75th percentile) | 4.23 (1.82-9.81)c | 3.07 (1.10-8.57)b |
LSI (continuous) | 1.95 (0.98-3.89) | 2.14 (1.08-4.27)b |
LSI ≥0.08 (25th percentile) | 2.26 (1.03-4.95)b | 2.19 (0.84-5.73) |
LSI ≥0.23 (Median) | 1.77 (0.93-3.38) | 3.27 (1.49-7.18)c |
LSI ≥0.63 (75th percentile) | 2.38 (1.12-5.06)b | 3.32 (1.52-7.23)c |
Abbreviations: CI, confidence interval; LSI, Larson-Skold Index; OR, odds ratio; Pb, lead; WLL, well lead level.
aP < .001.
b.01 ≤ P < .05.
c.0001 < P <.01.