Table 4.

Marking of sampled node with clip and imaging-guided localization.

Variable No. (%)
Imaging modality used to clip the node N = 296
 Ultrasound 293 (99.0%)
Type of clip used to mark the positive node N = 296
 Direct magseed 16 (5.4%)
 Direct radioactive seed 1 (0.3%)
 Nitinol ring marker (nickel titanium alloy) 91 (30.7%)
 Titanium or stainless steel marker with gel 92 (31.1%)
 Titanium or stainless steel marker without gel 88 (29.7%)
Imaging-guided localization of the clipped node: attempted N = 296
 Yes 257 (86.8%)
 No 39 (13.2%)
Imaging-guided localization of the clipped node: successful N = 257
 Yes 242 (94.2%)
 Unsure 7 (2.7%)
 No 8 (3.1%)
Reason for failure N = 257
 Clip not visible 6 (2.3%)
 Wire missed target 2 (0.8%)
Localization performed before surgery 185/257 (72.0%)
Imaging modality used to localize the clipped node (before surgery)
 Ultrasound 180 (97.3%)
 Computed tomography 2 (1.1%)
Type of localization used (before surgery)
 Magseed 5 (2.7%)
 ROLL 52 (28.1%)
 Radioactive seed 21 (11.4%)
 Tattoo 4 (2.2%)
 Wire 93 (50.3%)
 Other 10 (5.4%)
Localization performed during surgery: 72/257 (28.0%)
Type of localization used (during surgery) N = 72
 Tattoo 2 (2.8%)
 Wire 43 (59.7%)
 Ultrasound alone 21 (29.2%)
 Other 6 (8.3%)