. 2021 Aug 26;14(9):849. doi: 10.3390/ph14090849

Table 7.

Changes of parameters describing SEC-RID chromatograms (retention time, area, asymmetry factor) of HA (0.4%) solutions after sterilization and during storage under the conditions of the accelerated and long-term tests. Changes to the chromatograms of the unsterilized solution are given in brackets.

Sterilization Conditions Fresh Solution Observed Changes During Storage
25 °C/60%RH—6 Months 40 °C/75%RH—6 Months
tR, min P Af tR, min P Af tR, min P Af
Without sterilization 6.010 560078 1.765 +0.028 +4.71% Nc +0.016 −4.16% +0.176
105 °C/30 min 5.998
(−0.012)
565425
(+0.95%)
1.848
(+0.083)
+0.003 +7.56% +0.327 +0.081 −1.27% +0.024
121 °C/20 min 5.997
(−0.013)
558036
(−0.36%)
1.793
(+0.028)
+0.071 +1.76% −0.079 +0.115 −4.19% −0.097
134 °C/12 min 6.164
(+0.154)
546165
(−2.48%)
1.717
(−0.048)
−0.069 +1.29% +0.034 −0.044 +1.33% +0.215

Note: tR—retention time; P—area; Af—asymmetry factor; Nc—no change.