Comparison of the proposed procedure with the previously reported voltammetric methods using ASV for the determination of Cd(II). The works are ranked according to the decreasing limit of detection.

Electrode Accumulation Time LOD Sample References
polyPCA/GE 125 s 0.142 μM freshwater and real water [32]
SWCNTs/Biomass/GCE 120 s 0.103 μM real water [33]
GQDs/NF/GCE 150 s 0.126 μM bivalve mollusks [34]
BOC/GCE 500 s 0.035 μM tap water [35]
Hg(Ag)FE 30 s 0.013 μM real water [36]
MFE/GCE 240 s 0.006 μM the constituent parts of
the illegal cigarettes
[37]
IL/GO/GCE 300 s 0.003 μM tap water [38]
MWCNT/GCE not specified 0.002 μM real water [39]
BiFE/GCE 60 s 0.008 × 10−1 μM real water [31]
GO@Fe3O4@2-CBT/GCE 180 s 0.027 × 10−2 μM real water [40]
CuF/GCE 210 s 0.017 × 10−2 μM real water [this work]
CuF/CN/SPE 210 s 0.013 × 10−2 μM real water [this work]

polyPCA/GE—graphite electrodes modified with poly(p-coumaric acid), SWCNTs/Biomass/GCE—glassy carbon electrode modified by a mixture of single walled carbon nanotubes and biomass, GQDs/NF/GCE—glassy carbon electrode modified with graphene quantum dots and Nafion, BOC/GCE—glassy carbon electrode modified bismuth oxycarbide, Hg(Ag)FE—renewable mercury film silver-based electrode, MFE/GCE—glassy carbon electrode modified mercury film, IL/GO/GCE—glassy carbon electrode modified graphene oxide and ionic liquid, MWCNT/GCE—glassy carbon electrode multi-walled carbon nanotube electrode, BiFE/GCE—glassy carbon electrode modified bismuth film, and GO@Fe3O4@2-CBT/GCE—glassy carbon electrode modified with magnetic graphene oxide modified with benzothiazole-2-carboxaldehyde.