Comparison of the literature regarding plasma/serum D-dimer n in the diagnosis of periprosthetic joint infection.

D-Dimer Infection Definition Cut Off (ng/mL) Sensitivity Specificity Serum/Plasma
Shahi et al., JBJS Am, 2017 [19] MSIS 2014 850 89% 93% not mentioned
Fu et al., JoA, 2019 [21] MSIS 2011 850 67% 60% Plasma
Xiong et al., JOSR, 2019 [22] MSIS 2011 756 81% 80% Serum
Pannu et al., JoA, 2020 [77] ICM 2013 850 96% 32% Serum
Qin et al., JoA, 2020 [24] MSIS 2014 1170 93% 75% Serum
Wu et al., JoA, 2020 [27] MSIS 2014 410 76% 67% Plasma
Huang et al., Orthopaedic Surgery, 2021 [28] MSIS 2014 1170 60% 85% Plasma