Table 1.
Nº 1 | Name 2 | Price (€) 3 | Acceleration Range (g) 4 | Frequency Range (Hz) 5 | Spectral Noise (µg/√Hz) 6 | Operation Temperature (°C) 7 | Structural Type 8 | Type 9 |
---|---|---|---|---|---|---|---|---|
1 | 3713B112G [33] | 2070.0 | ±2.0 | [0.00, 250] | 22.90 | [−54, +121] | Wind Turbine [34] | Tri, M |
2 | 356B08 [35] | 1610.0 | ±50.0 | [0.50, 5000] | 40.00 | [−54, +77] | Bridge Crane [36] | Tri, P |
3 | 356A45 [37] | 1410.0 | ±50.0 | [0.70, 7000] | 125.00 | [−54, +85] | Forward Swept Wing [38] | Tri, P |
4 | 356B18 [39] | 1300.0 | ±5.0 | [0.50, 3000] | 11.40 | [−30, +77] | Motorbike Speedway Stadium [40] | Tri, P |
5 | KB12VD [41] | 828.0 | ±0.6 | [0.30, 2000] | 0.06 | [−20, +80] | Concrete School Building [42] | Uni, P |
6 | 3711B1110G [43] | 870.0 | ±10.0 | [0.00, 1000] | 107.90 | [−54, +121] | Railroad Bridges [44] | Uni, M |
7 | KS48C [41] | 750.0 | ±6.0 | [0.25, 130] | 0.60 | [−20, +120] | Footway Bridge [45] | Uni, P |
8 | 393B12 [46] | 820.0 | ±0.5 | [0.15, 1000] | 1.30 | [−54, +82] | Historical Masonry Structures [47] | Uni, P |
9 | 393A03 [48] | 710.0 | ±5.0 | [0.50, 2000] | 2.00 | [−54, +121] | Brick Masonry Constituents [49] | Uni, P |
10 | 352A24 [50] | 540.0 | ±50.0 | [1.00, 8000] | 80.00 | [−54, +121] | Hallow Square Beams [51] | Uni, P |
11 | 352C33 [52] | 380.0 | ±50.0 | [0.50, 10,000] | 39.00 | [−54, +93] | Bridges [53] | Uni, P |
12 | ADXL335 [54] | 10.7 | ±3.6 | [0.50, 550] | 300.00 | [−40, +85] | Bridges [55] | Tri, M |
13 | LIS344ALH [56] | 12.0 | ±2.0 | [1.00, 500] | 50.00 | [−40, +85] | Steel beam [57] | Tri, M |
14 | MPU9250 [3] | 5.8 | ±16.0 | [0.24, 500] | 300.00 | [−40, +85] | Steel Pile and Column [58] | Tri, M |
15 | MPU6050 [59] | 5.4 | ±16.0 | [0.24, 500] | 400.00 | [−40, +85] | Building Model [60] | Tri, M |
Notes: 1 Sensor number. 2 Sensor name. 3 Sensor price: the prices are obtained from retailers (VAT excluded). 4 Acceleration range: the maximum acceleration amplitude capacity of the sensors. 5 Frequency range: the accurate, readable range of frequencies. 6 Spectral Noise: the power spectral density of noise per unit of bandwidth (1 Hz). 7 Operational temperature: temperature range where the sensor works accurately. 8 Structural type: where the sensors are used. 9 Type: Uni stands for uniaxial, Tri for triaxial, P for piezoelectric and M for MEMS (uniaxial accelerometers are only capable of sensing vibration from one axis, while triaxial ones can sense vibrations from all of the directions).