Skip to main content
. 2021 Sep 10;11(9):1659. doi: 10.3390/diagnostics11091659

Table 3.

IFN-γ values and active TB exposure history for 11 HCWs with discordant results between Standard E TB-Feron ELISA (positive) and QuantiFERON-TB Gold Plus assays (negative).

No. Standard E TB-Feron ELISA Previous Active TB Treatment History TB Exposure History of within 2 Years
Primary Test Resampling Test
TB–nil (IU/mL) Result TB–nil (IU/mL) Result
1 0.40 Positive 0.24 Negative No Yes
2 0.35 Positive 0.36 Positive No No
3 0.80 Positive 0.22 Negative No Yes
4 0.39 Positive 0.20 Negative No No
5 0.95 Positive 0.94 Positive No Yes
6 0.43 Positive 0.32 Negative No Yes
7 0.58 Positive 0.03 Negative No Yes
8 0.72 Positive 0.74 Positive No No
9 0.39 Positive 0.10 Negative No Yes
10 0.39 Positive 0.46 Positive No Yes
11 0.68 Positive ND No No

HCW, healthcare worker; ND, not done.