Skip to main content
. 2021 Sep 18;11(9):1709. doi: 10.3390/diagnostics11091709

Table 2.

Sensitivity and antibodies levels of ELISA (QuantiVac ELISA IgG, Euroimmun) and Maglumi (IgG anti-RBD, SNIBE) methods in the different patient’s specimens subdivided in time frames according to the day from the onset of symptoms.

Positivity Rate ELISA Levels (RU/mL) Maglumi Levels (AU/mL)
Days from Symptoms’ Onset n of Specimens ELISA Maglumi 25 Percentile Median 75 Percentile 25 Percentile Median 75 Percentile
≤11 * 17 41.2% 76.5% 2.4 10.3 37.1 1.0 3.1 14.1
12–16 * 15 73.3% 80.0% 6.7 68.1 404.0 2.3 24.9 50.6
17–22 14 100.0% 100.0% 76.8 191.5 438.0 25.6 48.8 58.1
23–43 16 100.0% 100.0% 137.5 250.5 448.5 43.2 50.5 61.5
46–72 15 100.0% 100.0% 183.2 259.2 330.2 49.8 82.7 126.0
81–162 * 16 93.7% 100.0% 57.8 102.6 149.0 23.1 34.6 53.1
168–371 * 15 86.7% 100.0% 29.4 39.6 110.3 13.9 22.2 48.1

Asterisks represent the classes of cases significantly different from that with higher concentrations.