Reference Data Variation Across Summary
Mottet et al. [42]
Cornford et al. [43]
(ESTRO)
CT and MRI images (prostate cancer) NA Provided guidelines procedures and methods for image-guided radiation therapy (IGRT) in prostate cancer
Boellaard et al. [45]
(EARL)
PET imaging Scan acquisition, image processing, image interpretation Provides guideline/regulations for oncology
Luh et al. [48]
(ASTRO)
NA NA Developed a ‘practice parameter’ for IGRT, and provided quality assurance standards, personnel qualifications, indications and guided documentation for imaging
Sachs et al. [51] CT and MRI images CT and MRI protocols Reduced the number of MRI protocols from 168 to 66 and CT protocols from 248 to 97 across scanners and centers by selecting an appropriate clinical-driven protocol and standardization process
Center for Drug Evaluation and Research (FDA) [52] NA Image acquisition parameters Provided guidelines to focus on image acquisition in clinical trials conducted to support authorization of drugs and biological products