Skip to main content
. 2021 Sep 8;14(18):5160. doi: 10.3390/ma14185160

Table 1.

Chemical composition of steel after vacuum degassing, before and after the addition of mischmetal, heat A [wt.%]. * Oxygen activity was measured by CELOX®, hydrogen by HYDRIS®.

Before/After REM Add C Mn Si P S Cu Ni Cr Mo Al Ce H * T [°C] ao *
Before 0.42 0.69 0.26 0.008 0.001 0.13 0.19 1.02 0.16 0.023 0.000094 1596 0.000385
After 0.42 0.70 0.26 0.007 0.001 0.13 0.19 1.03 0.16 0.024 0.035 N/A 1573 0.000120