Skip to main content
. 2021 Sep 27;11:19094. doi: 10.1038/s41598-021-98695-1

Table 2.

The sensitivity and specificity of MediPost according to the measuring parameters. For comparison purposes the results of specificity for length and surface were adjusted to the value obtained for sway velocity.

Condition Measurement parameter AUC p Sensitivity Specificity PPV NPV Difference between sensitivity
Head shaking posturography 0.3 Hz
1st Velocity 0.64 0.01 92 43 48 90 0.0%
Length 0.65 0.006 90 43 47 88 2.9%
Surface 0.69 <.001 92 43 48 90 0.0%
2nd Velocity 0.64 0.01 50 80 60 73 0.0%
Length 0.65 0.01 47 80 58 73 5.3%
Surface 0.62 0.009 34 80 52 68 31.6%
3rd Velocity 0.82 <.001 74 82 70 84 3.4%
Length 0.85 <.001 76 82 71 86 0.0%
Surface 0.85 <.001 68 82 68 82 10.3%
4th Velocity 0.95 <.001 87 96 92 93 0.0%
Length 0.96 <.001 87 96 92 93 0.0%
Surface 0.94 <.001 79 96 91 89 9.1%
Head shaking posturography 0.6 Hz
1st Velocity 0.70 0.001 58 79 61 76 0.0%
Length 0.69 <.001 50 79 58 73 9.5%
Surface 0.69 0.001 45 79 55 71 19.0%
2nd Velocity 0.68 0.001 66 74 60 79 0.0%
Length 0.69 <.001 58 74 56 75 12.0%
Surface 0.67 0.003 50 74 53 72 24.%
3rd Velocity 0.87 <.001 74 92 85 86 0.0%
Length 0.90 <.001 72 92 84 85 3.6%
Surface 0.89 <.001 68 92 84 84 7.1%
4th Velocity 0.92 <.001 82 88 80 89 6.1%
Length 0.93 <.001 82 88 80 89 6.1%
Surface 0.93 <.001 87 88 81 92 0.0%

Conditions: 1st (eyes open/stable surface), 2nd (eyes closed/stable surface), 3rd (eyes open/foam), 4th (eyes closed/foam).

The most significant results are in bold.

AUC area under curve, PPV positive predictive value, NPV negative predictive value.