Skip to main content
. 2021 May 26;406(6):2107–2115. doi: 10.1007/s00423-021-02206-9

Table 2.

Donor-, intraoperative-, and organ-specific parameters in patients with modified liver and kidney transplantation

Patient-ID Average (SD)
P-001 P-002 P-003 P-004 P-005 P-006 P-007
Donor-specific parameter Age 55 79 61 72 63 61 51 -
Sex (M/F) M F F F F F F -
Body weight (kg) 90 60 63 80 70 72 60 -
Body height (m) 1.90 1.60 1.70 1.65 1.70 1.67 1.60 -
BMI (kg/m2) 24.90 23.40 21.80 29.40 24.20 25.80 23.40 -
Extended donor Yes (1) Yes (2, 3) Yes (1, 3) Yes (1, 2) Yes (3–5) Yes (3) Yes (5) -
Intraoperative parameter Operation time (min) 326 236 288 413 322 419 393 342.43 (±68.77)
CIT liver (min) 420 516 535 497 395 621 208 456 (±132.46)
WIT liver (min) 25 31 32 29 32 56 46 35.86 (±11.01)
Cell-saver (ml) 0 400 0 335 300 250 241 218 (±158.19)
CIT kidney (min) 559 563 648 457 488 741 550 572.29 (±95.05)
WIT kidney (min) 12 10 21 10 20 21 34 18.29 (±8.58)
PRC (n) 3 1 0 0 4 2 4 2 (±1.73)
PLC (n) 0 0 0 0 0 0 0 0
FFP (n) 0 0 0 2 3 0 0 0.71 (±1.25)
Organ-specific parameter Liver vol. (ml) 11300 7394 6263 9867 10243 4576 15758 9343 (±3698.56)
Kidney vol. rig. (ml) 2931 1899 1408 4336 3881 1714 3221 2770 (±1128.78)
Liver weight (g) 4500 3600 4220 4960 5585 1775 8210 4692.86 (±1966.66)
Kidney weight (g) 2000 1028 1900 3860 2908 984 1635 2045 (±1032)

Values are presented as the average and standard deviation (SD); CT-volumetry using CT Revolution 256 slice, GE Healthcare, USA; Cerner SkyVue® Distribution, version 2014.01.05, Cerner, USA; M, male, F, female; BMI, body mass index; extended donor criteria reason, 1.: nontraumatic subarachnoid hemorrhage, 2.: donor age, 3.: ICU stay more than 7 days, 4.: cancer in medical history, 5.: limited graft function; WIT, warm ischemic time; CIT, cold ischemic time; PRC, packed red cells; PLC, platelets; FFP, fresh-frozen plasma; vol, volume