Analysis of results with different activation functions for the proposed quad channel hybrid model.

Optimizer Dataset (%) Accuracy (%) Precision (%) Recall (%) F1-score (%)
ReLU Hallmarks 71.92 70.92 68.62 69.75
AIM 92.17 88.83 86.91 87.85

Sigmoid Hallmarks 69.71 64.72 60.81 62.70
AIM 55.31 50.90 52.21 51.54

SoftPlus Hallmarks 70.49 64.97 66.91 65.92
AIM 77.73 74.91 72.82 73.85

Hard sigmoid Hallmarks 64.35 61.75 60.81 61.27
AIM 89.48 86.22 85.22 85.71