Skip to main content
. 2021 Oct 3;55(5):1277–1285. doi: 10.1007/s43465-021-00538-8

Table 1.

Demographics and medical details of the patient with periprosthetic fracture having unique pattern with their follow-up score

Name initials Age (years)/gender Fractured implant design Duration since index surgery Removal technique Revision technique (Year of surgery)
Follow-up (years)
HHS
L. J 68/F Uncemented fully coated cylindrical stem 6 years

Proximal fragment: ETO

Distal fragment: multiple K-wires + trephines

Distal locking long revision stem supplemented with strut allografts

(2012)

9 years

90
S. S 55/F Uncemented fully coated long cylindrical stem 3 years

Proximal fragment: loose, removed with ease

Distal fragment: multiple K-wires + trephines

Allograft prosthesis composite supplemented with strut allografts

(2013)

8 years

84
J. A 66/F AMP 11 years

Proximal fragment: reciprocating saw + reverse hitting

Distal fragment: vise grip pliers

Revision Modular stem prosthesis Died after 7 years of revision surgery due to malignancy
D.S 52/M Bipolar stem 4 years

Proximal fragment: reverse hitting

Distal fragment: multiple K-wires + trephines

Long cylindrical stem

(2014)

7 years

92
A.R 44/M Cemented long stem 6 years

Proximal fragment: excised

Distal fragment: multiple K- wires + trephine

Allograft prosthesis composite supplemented with strut allografts

(2014)

7 years

90
S. B 70/F Uncemented fully coated long cylindrical stem 10 years

Proximal fragment: ETO

Distal fragment: multiple K-wires + trephine

Distally locking long HA coated stem

(2016)

5 years

80
B. S 50/M Uncemented fully coated long cylindrical stem 8 years

Proximal fragment: multiple K wires + episiotomy + proximal slap hammering of vise grip plier

Distal fragment: multiple K-wires + trephines

Revision long cylindrical stem

(2017)

4 years

88
S. P 42/M Uncemented fully coated cylindrical stem 4 years

Proximal fragment: loose, removed with ease

Distal fragment: multiple K-wires + trephines

Long conical stem

(2018)

3 years

90
H.S 62/M Bipolar stem 5 years

Proximal fragment: ETO

Distal fragment: multiple K-wires + trephines

Long cylindrical stem

(2018)

3 years

86
A.K. G 55/M Uncemented fully coated long cylindrical stem 4 years

Proximal fragment: loose, removed with ease

Distal fragment: multiple K-wires + trephines

Long conical stem

(2019)

2 years

86
M.D 61/M Cemented long stem 10 years

Proximal fragment: loose with poor bone stock

Distal fragment: multiple K-wires + trephines

Allograft prosthesis composite

(2019)

2 years

82

M male, F female, AMP Austin Moore prosthesis, ETO extended trochanteric osteotomy, HA hydroxyapatite