. 2021 Jun 25;59(10):1041–1047. doi: 10.1093/mmy/myab038

Table 1.

Sensitivity and specificity of the SQ and CryptoPS assays for detection of CrAg in frozen-thawed plasma from HIV-seropositive patients with a CD4 count of <100 cells/μl compared to a reference lateral flow assay

Statistic SQ assay 95% CI CryptoPS assay 95% CI
Sensitivity (%) 98.33 91.06–99.99 90 79.49–96.24
Specificity (%) 100 97.28–100 94.1 89.5–97.9
Positive likelihood ratio >100 15.19 7.71–29.90
Negative likelihood ratio 0.02 0.00–0.12 0.11 0.05–0.23

Note: Cryptococcal antigen (CrAg) enzyme immune-assay (EIA) results for the 194 participants were positive for 58 and negative for 136. Compared to the EIA, the sensitivity and specificity of the semi-quantitative (SQ) qualitative results were 100% (58/58) and 99% (135/136) while Crypto PS had 91.4% (53/58) sensitivity and 93.4% (127/136) specificity.