Skip to main content
. 2021 Oct 1;17(10):2029–2039. doi: 10.5664/jcsm.9378

Table 3.

Prevalence of moderate-severe OSA (AHI > 15 events/h) in 3 studies of the Busselton population.

Reference Device n Age Range (y) Monitoring Prevalence OSA
Male Female
2 MESAM IV 400 40–69 (males only) Snoring, oximetry, body position, heart rate 4.7%
24 ApneaLink 793 18–80 Oximetry 12.4% 5.7%
24 ApneaLink 359 46–69* ApneaLink 24.6% 9.8%
Present study ApneaLink 2,707 46–69 Oximetry, nasal flow 20.2% 10.0%

*Recalculated from original data. AHI = apnea-hypopnea index, OSA = obstructive sleep apnea.