Skip to main content
. 2021 Sep 23;8:695531. doi: 10.3389/fcvm.2021.695531

Table 3.

Comparison of clinical characteristics and periprocedural complications between LBBAP and RVP.

Variables LBBAP (n = 406) RVP (n = 313) P -value
Age 64.9 ± 14.3 67.5 ± 12.2 0.573
Male 197 (48.5%) 150 (47.9%) 0.940
Pacing indications <0.001
   AVB 245 (60.3%) 86 (27.5%)
   SND 161 (39.7%) 227 (72.5%)
Type of device <0.001
   Double-chamber PM 341 (84.0%) 297 (94.9%)
   Single-chamber PM 65 (16.0%) 16 (5.1%)
Periprocedural complications
   Lead revision 2 2 0.658
      Lead dislodgement 1 2
      Lead perforation 1 0
   Pericardial effusion 0 0 1
   Pacing system infection 0 0 1
   Pocket hematoma 0 0 1
   Pneumothorax/hemothorax 0 0 1

Data are presented as mean ± standard deviation for continuous variables and frequency and percentages for categorical variables.

LBBAP, left bundle branch area pacing; RVP, right ventricular pacing; AVB, atrioventricular block; SND, sinus node dysfunction; PM, pacemaker.