Repeated reverse kinematics accuracy tests on large wrap for index finger (first 4 columns) and thumb (last 3 columns).

Joint Test 1 Test 2 Test 3 Test 4 Test 5 Standard deviation
J0 (degree) 30.038 30.052 30.009 30.088 30.016 0.028238
MCP (degree) 30.057 30.151 30.098 30.139 30.110 0.033075
PIP (degree) 45.120 45.108 45.085 45.177 45.046 0.043069
DIP (degree) 45.072 45.057 45.004 45.105 45.095 0.035556
J0 (degree) 179.984 180.081 180.014 180.041 179.990 0.035704
MCP (degree) 30.113 30.018 30.101 30.098 30.052 0.035825
IP (degree) 75.037 75.012 75.022 75.079 75.031 0.023007