Skip to main content
. 2021 Aug 25;22(10):82–93. doi: 10.1002/acm2.13399

TABLE 1.

Institutional guidelines and ethos template goals for prostate plans

Ethos assigned priority Structure Institutionalclinical values (54 Gy + 24 Gy boost) Ethos planning goals (54 Gy plan only) Reportedmetrics for this study
1 Most Important PTV D95.0% ≥100.0% D95.0% ≥100%
2 Very Important CTV Dmean ≥100.0% Dmean ≥100% D98%
Very Important PTV Dmax < 107.0% Dmax (0.10 cm 3 ) < 107.0%
Very Important PTV Dmin > 95.0% Dmin (0.10 cm 3 ) > 95.0%
Very Important Rectum V70Gy < 20.0% V48.50 Gy < 20.0% V90% < 20.0%
Very Important Rectum V60Gy < 25.0% V41.50 Gy < 25.0% V75 % < 25.0%
Very Important Rectum V40Gy < 35.0% V27.70 Gy < 35.0% V50% < 35.0%
3 Important Bladder V70Gy < 25.0% V48.50 Gy < 25.0% V90% < 25.0%
Important Bladder V60Gy < 35.0% V41.50 Gy < 35.0% V75 % < 35.0%
Important Bladder V40Gy < 45.0% V27.70 Gy < 45.0% V50 % < 45.0%
Important Bowel Dmax < 54.0 Gy Dmax < 27.40 Gy
4 Less Important Femur left V50Gy < 10.0% V34.60 Gy < 10.0%
Less Important Femur right V50Gy < 10.0% V34.60 Gy < 10.0%
Less Important Penile bulb Dmean < 52.5 Gy Dmean < 26.06 Gy