Table 4.

Accuracy of ROTEM parameters and platelet count for the association with clinically evident VTE

Parametera Area under the curve (95% CI) Optimal cutoff Sensitivity (%) Specificity (%)
Preoperative EXTEM A10 0.75 (0.61-0.88) ≥ 57 73 80
Preoperative EXTEM MCF 0.84 (0.75-0.92) ≥ 69 81 79
Preoperative EXTEM CFT 0.88 (0.81-0.96) ≤ 81 90 76
Preoperative INTEM A10 0.68 (0.56-0.79) ≥ 60 91 53
Preoperative INTEM MCF 0.79 (0.71-0.87) ≥ 67 90 62
Preoperative INTEM CFT 0.89 (0.81-0.97) ≤ 65 81 86
Postoperative INTEM A10 0.81 (0.71-0.90) ≥ 64 91 65
Postoperative INTEM MCF 0.85 (0.80-0.90) ≥ 75 100 75
Postoperative INTEM CFT 0.80 (0.69-0.91) ≤ 56 78 73

The area under the curve and optimal cutoff (Youden index) values with corresponding sensitivity and specificity are presented; A10 = clot amplitude at 10 minutes; MCF = maximum clot firmness; CFT = clot formation time.

a

Preoperative INTEM clot formation time, preoperative EXTEM clot formation time, and postoperative INTEM maximum clot firmness demonstrated the highest levels of accuracy.