Table 3.

Ultrasound Diagnostic Values for Any-Sized Tear and for Partial- vs Full-Thickness Supraspinatus Tears a

Any-Sized Rotator Cuff or Biceps Tear Partial- vs Full-Thickness Supraspinatus Tears
Supraspinatus Subscapularis Biceps Full Thickness Partial Thickness
No. of studies (shoulders) 17 (1448) 3 (425) 3 (282) 17 (1516) 15 (1407)
Diagnostic values
 Diagnostic accuracy 0.83 (0.66-0.97) 0.76 (0.68-0.80) 0.93 (0.88-0.97) 0.93 (0.67-0.97) 0.81 (0.45-0.93)
 Sensitivity 0.89 (0.70-1.00) 0.30 (0.13-0.39) 0.61 (0.58-0.80) 0.88 (0.50-0.96) 0.65 (0.08-1.00)
 Specificity 0.73 (0.29-1.00) 0.97 (0.93-1.00) 0.99 (0.98-1.00) 0.93 (0.59-1.00) 0.86 (0.56-0.96)
 NPV 0.80 (0.11-1.00) 0.76 (0.68-0.78) 0.94 (0.86-0.99) 0.91 (0.64-0.98) 0.91 (0.57-1.00)
 PPV 0.93 (0.61-1.00) 0.73 (0.67-1.00) 0.92 (0.67-1.00) 0.89 (0.67-1.00) 0.68 (0.10-0.93)

a Diagnostic values are reported as median (range). NPV, negative predictive value; PPV, positive predictive value.