Skip to main content
. 2021 Oct 8;21(19):6676. doi: 10.3390/s21196676

Table 2.

Experimental results corresponding to the rod-to-plane electrode geometry. CEV versus environmental pressure and supply frequency.

Pressure Test Sensor 50 Hz 200 Hz 400 Hz 600 Hz 800 Hz 1000 Hz
100 kPa Test 1 Camera 3761.5 3817.1 3784.0 3792.0 3659.9 3579.1
Leakage current 3723.2 3788.1 3754.5 3792.0 3659.9 3579.1
Test 2 Camera 3802.3 3781.0 3826.3 3899.8 3798.5 3732.3
Leakage current 3774.4 3781.0 3826.3 3835.9 3798.5 3732.3
Test 3 Camera 3800.7 3819.6 3807.1 3795.8 3843.2 3779.7
Leakage current 3763.9 3800.5 3786.8 3774.7 3843.2 3779.7
Average 3788.2 3805.9 3805.8 3829.2 3767.2 3697.0
80 kPa Test 1 Camera 3382.9 3414.8 3410.6 3441.2 3341.8 3146.4
Leakage current 3326.5 3377.3 3410.6 3430.5 3341.8 3146.4
Test 2 Camera 3367.0 3398.1 3412.6 3424.6 3358.8 3272.4
Leakage current 3348.2 3379.1 3373.0 3404.0 3358.8 3272.4
Test 3 Camera 3385.4 3377.7 3412.9 3415.1 3358.1 3271.9
Leakage current 3329.1 3359.3 3393.4 3404.2 3358.1 3271.9
Average 3378.4 3396.9 3412.1 3427.0 3352.9 3230.2
60 kPa Test 1 Camera 2757.9 2774.2 2761.2 2763.5 2791.7 2689.5
Leakage current 2719.8 2736.0 2742.6 2742.2 2781.3 2688.1
Test 2 Camera 2798.5 2842.9 2861.9 2868.7 2873.7 2813.1
Leakage current 2778.4 2823.8 2842.3 2837.2 2851.0 2813.1
Test 3 Camera 2853.7 2918.9 2901.8 2909.8 2916.8 2837.4
Leakage current 2815.5 2851.7 2862.4 2889.6 2916.8 2837.4
Average 2803.4 2845.3 2841.7 2847.3 2860.7 2780.0
40 kPa Test 1 Camera 2255.6 2267.0 2270.0 2270.7 2274.6 2254.3
Leakage current 2198.5 2248.1 2270.0 2249.5 2274.6 2254.3
Test 2 Camera 2266.1 2315.4 2330.7 2333.9 2366.7 2354.2
Leakage current 2227.7 2296.3 2330.7 2333.9 2366.7 2354.2
Test 3 Camera 2246.4 2316.4 2321.5 2313.3 2322.5 2308.0
Leakage current 2246.4 2297.3 2321.5 2313.3 2322.5 2308.0
Average 2256.0 2299.6 2307.4 2306.0 2321.2 2305.5
20 kPa Test 1 Camera 1468.8 1520.2 1522.6 1529.0 1526.7 1529.8
Leakage current 1449.3 1520.2 1522.6 1529.0 1526.7 1529.8
Test 2 Camera 1374.7 1443.1 1444.3 1426.4 1439.3 1458.0
Leakage current 1355.2 1443.1 1444.3 1426.4 1439.3 1458.0
Test 3 Camera 1450.2 1474.0 1463.6 1488.5 1552.0 1629.1
Leakage current 1450.2 1474.0 1463.6 1488.5 1552.0 1629.1
Average 1431.2 1479.1 1476.8 1481.3 1506.0 1539.0

Electrode diameter = 1.5 mm, tip angle = 90°, electrode tip to plane distance = 8 mm.