Skip to main content
. 1999 Jul;37(7):2223–2229. doi: 10.1128/jcm.37.7.2223-2229.1999

TABLE 4.

Performance characteristics of EIA and PACE 2, LCx, and AMP CT assays for detection of C. trachomatis

Specimen and assay Sensitivity (%) Specificity (%) PPV (%) NPV (%)
Endocervical swabs
 Clearview EIA 50 (5/10)a 100 (55/55) 100 (5/5) 91.7 (55/60)
 Gen-Probe PACE 2 80.6 (50/62) 99.9 (675/676) 98.0 (50/51) 98.3 (675/687)
 Abbott LCx 96.8 (60/62) 99.9 (675/676) 98.4 (60/61) 99.7 (675/677)
 Gen-Probe AMP CT 100 (62/62) 99.9 (675/676) 98.4 (62/63) 100 (677/677)
Urine
 Abbot LCx 98.4 (61/62) 100 (685/685) 100 (61/61) 99.9 (685/686)
 Gen-Probe AMP T 80.6 (50/62) 100 (685/685) 100 (50/50) 98.2 (685/697)
a

Values in parentheses are number of specimens positive by the assay/total number of specimens tested.