Skip to main content
. 2021 Aug 26;6(5):1110โ€“1115. doi: 10.1002/lio2.631

TABLE 2.

Pressure gradients during different stages of balloon Eustachian tuboplasty

Preinsertion to insertion Range โˆ’83 to +234 daPa
Average +8.3 daPa
๐œŽ 45
Insertion to inflation Range โˆ’515 to +18 daPa
Average โˆ’26.6 daPa
๐œŽ 96
Inflation to 1โ€minute inflation Range โˆ’12 to +418 daPa
Average + 22.8 daPa
๐œŽ 80
1โ€minute inflation to deflation Range โˆ’124 to +27 daPa
Average โˆ’1.9 daPa
๐œŽ 24
Deflation to withdrawal Range โˆ’11 to +18 daPa
Average +1.1 daPa
๐œŽ 8
Preprocedure to withdrawal Range โˆ’84 to +115 daPa
Average +10.6 daPa
๐œŽ 54
Preprocedure to 4โ€weeks post procedure Range โˆ’97 to +138 daPa
Average +4.4 daPa
๐œŽ 49

Note: ๐œŽ = SD.