Skip to main content
. 2021 Oct 1;12:688183. doi: 10.3389/fimmu.2021.688183

Figure 3.

Figure 3

The number of “true calls” and “false call” of concordant calls according to the number of the concordant calls (A). The “true calls” means that the number of calls that match the HLA type of the 1000 Genome Project data among the concordant calls presented by eight tools. The “false calls” means that the number of calls that do not match the HLA type of the 1000 Genome Project data among the concordant calls presented by eight tools. “Precision”, “Recall”, and “F1 score” according to the number of concordant calls (B). Precision and recall are calculated using “true calls” and “false calls”, and F1 scores are obtained using these two. The detailed formula is given in the text.