Table 3.
Error [mm] | |||||||
---|---|---|---|---|---|---|---|
k | 25% | 50% | 75% | 100% | 125% | 150% | 175% |
Param (default value) | Reference | ||||||
SB (3 [mm]) | 3.3002 | 2.7002 | 3.3002 | 0.0 | 10.5750 | 19.7250 | 24.9750 |
TB (−300 [HU]) | 80.2767 | 39.3823 | 10.9500 | 0.0 | 3.1501 | 3.9002 | 3.5253 |
TS (320 [HU]) | 77.9674 | 41.8941 | 31.0902 | 0.0 | 24.7194 | 42.3552 | 65.1209 |
SS (100 × 15 × 15 [mm]) | 28.8292 | 22.3974 | 10.0019 | 0.0 | 21.7733 | 28.1594 | 31.8916 |
TLA (−200 [HU]) | 88.2000 | 25.4250 | 0.3750 | 0.0 | 0.6750 | 0.7500 | 1.2750 |
DBA (1 [mm]) | 0.0000 | 0.0000 | 0.0000 | 0.0 | 0.0000 | 0.2250 | 0.2250 |
DSA (30 [mm]) | 0.6750 | 0.6000 | 0.4500 | 0.0 | 2.7000 | 3.2250 | 5.1000 |