Skip to main content
. 2021 May 5;36(10):2875–2883. doi: 10.1111/jgh.15522

Table 4.

Performance comparison between the four radiologists with AI assistance on the testing set

Statistics ACC Se Sp PPV NPV
Expert1 0.924 (0.888, 0.960) 0.970 (0.943, 0.996) 0.766 (0.645, 0.887) 0.935 (0.898, 0.972) 0.878 (0.778, 0.978)
Expert2 0.929 (0.894, 0.964) 0.982 (0.961, 1.000) 0.745 (0.620, 0.869) 0.931 (0.893, 0.968) 0.921 (0.835, 1.000)
Resident1 0.910 (0.871, 0.949) 0.970 (0.943, 0.996) 0.702 (0.571, 0.833) 0.919 (0.878, 0.960) 0.868 (0.761, 0.976)
Resident2 0.919 (0.883, 0.956) 0.994 (0.982, 1.000) 0.660 (0.524, 0.795) 0.911 (0.869, 0.952) 0.969 (0.908, 1.000)
P 0.904 0.360 0.671 0.818 0.460

ACC, accuracy; Se, sensitivity; Sp, specificity. Bold fonts indicate the best performance per column.