Table 1.
Complex |
max(VIS) [nm] |
Φ(VIS)[a] |
(VIS)[b] [ns] |
max(NIR) [nm] |
Φ(NIR)[a] |
(step‐scan) [ns] |
---|---|---|---|---|---|---|
Cr |
≈695 |
– |
– |
≈965 |
– |
380±10 |
Mo |
666 |
1.1 ⋅ 10−4 |
8.1±0.1 (91 %) |
926 |
9 ⋅ 10−4 |
600±10 |
W |
673 |
1.7 ⋅ 10−4 |
2.04±0.06 (99 %) |
918 |
1.4 ⋅ 10−3 |
370±10 |
[a] The error bars for the photoluminescence quantum yields are estimated to ±25 % according to the literature. [b] For the main component (relative contribution in brackets). [38]