Skip to main content
. 2021 Oct 13;15:4097–4108. doi: 10.2147/OPTH.S325618

Table 3.

IOP Safety Parameters in Study Eyes (Safety Population)

Parameter, n (%)* DEX (N = 145) Laser (N = 129)
AE* 59 (40.7) 5 (3.9)
IOP at any time during the study
 ≥25 mmHg 49 (33.8) 6 (4.7)
 ≥35 mmHg 3 (2.1) 0 (0)
 Increase of ≥10 mmHg from baseline 48 (33.1) 2 (1.6)
Use of IOP-lowering topical medication during the study 50 (34.5) 3 (2.3)
Surgical procedure during the study to lower IOP 1 (0.7) 0 (0)

Notes: *Any treatment-emergent AE related to elevated IOP, Trabeculectomy.

Abbreviations: AE, treatment-emergent adverse event; DEX, dexamethasone intravitreal implant 0.7 mg; IOP, intraocular pressure.