Table 6:
Suggested imaging conditions for methods described in this chapter
FP/Dye | Excitation/Emission | Light source | Exposure time2 |
---|---|---|---|
Cit1-GFP | 488/507 | LED 470 nm (100%) or Metal-Halide Lamp + standard GFP Filter | 100 ms |
Tom70-mCherry | 587/610 | Metal-halide lamp + standard DsRed filter | 200 ms |
MitoTracker Red (100 nM for 30 min) | 581/644 | Metal-halide lamp + standard DsRed filter | 200 ms |
DiOC6 | 482/504 | LED 470 nm (100%) | 50 ms |
roGFP (Oxidized) | 365/507 | LED 365 nm (25%) | 100 ms |
roGFP (Reduced) | 470/507 | LED 470 nm (100%) | 100 ms |
DHE (40 μM for 30 min) | 485/530 | Metal-halide lamp + standard DsRed filter | 100 ms |
Abp140-GFP | 488/507 | LED 470 nm (100%) or Metal-Halide Lamp + standard GFP Filter | 300 ms |
Abp1-mCherry | 587/610 | Metal-halide lamp + standard DsRed filter | 200 ms |
Cit1-mCherry | 587/610 | Metal-halide lamp + standard DsRed filter | 200 ms |
These are recommended concentrations, and can be adjusted as needed
These are recommended exposure times and can be adjusted as needed