Titration of three plasma samples using Roche Monitor version 2.0

Input sample (no. of RNA copies/ml)a Test dilution Sample
Internal control
Virus load (no. of RNA copies/ml)
Dilution OD450 Dilution OD450
Genotype 1 (7.4 × 106) 1:1 1:625 0.500 1:25 0.958 2.47 × 105
1:10 1:125 0.535 1:25 0.441 1.08 × 106
1:31.6 1:125 0.398 1:25 0.598 1.77 × 106
1:100 1:125 0.191 1:25 0.550 2.24 × 106
1:316 1:25 0.203 1:25 0.511 1.67 × 106
1:1,000 1:5 0.252 1:25 0.493 1.51 × 106
1:3,160 1:1 0.457 1:25 0.456 2.20 × 106
1:10,000 1:1 0.150 1:25 0.483 1.35 × 106
Genotype 2 (2.4 × 107) 1:1 1:625 0.515 1:25 0.842 2.94 × 105
1:10 1:125 0.781 1:25 0.626 1.30 × 106
1:31.6 1:125 0.530 1:25 0.789 2.06 × 106
1:100 1:125 0.214 1:25 0.734 2.21 × 106
1:31.6 1:125 0.150 1:25 0.731 3.89 × 106
1:1,000 1:25 0.191 1:25 0.814 3.32 × 106
1:3,160 1:5 0.314 1:25 0.525 6.92 × 106
1:10,000 1:5 0.192 1:25 0.418 1.43 × 107
Genotype 3 (1.7 × 107) 1:1 1:625 0.563 1:25 0.865 3.16 × 105
1:10 1:125 0.869 1:25 0.571 1.63 × 106
1:31.6 1:125 0.447 1:25 0.351 4.33 × 106
1:100 1:125 0.270 1:25 0.506 4.68 × 106
1:316 1:25 0.360 1:25 0.407 5.56 × 106
1:1,000 1:25 0.256 1:25 0.495 9.19 × 106
1:3,160 1:25 0.166 1:25 0.565 1.25 × 107
a

Virus load in test specimens was determined by limiting dilution.