TABLE 7.

Actual volumes per brain structure for all three MRI systems.

Brain structures Volumes (mean ± SD, in mL)
Achieva Ingenia GE All scanners p-value
Whole brain 1139.77 ± 130.19# 1132.64 ± 129.54#• 1142.20 ± 132.82 1138.20 ± 126.33 <0.001
Gray matter 683.08 ± 80.55 679.19 ± 81.76 649.16 ± 87.20∧• 670.47 ± 81.77 <0.001
Cortical gray matter 650.81 ± 79.06 646.72 ± 80.56 620.57 ± 85.32∧• 639.37 ± 79.99 <0.001
White matter 456.69 ± 52.48 453.45 ± 50.43 493.04 ± 53.18∧• 467.73 ± 53.43 <0.001
Frontal cortex 180.02 ± 24.40 179.09 ± 23.39 168.67 ± 24.96∧• 175.93 ± 23.99 <0.001
Parietal cortex 111.81 ± 14.35 111.75 ± 14.45 105.07 ± 17.05∧• 109.54 ± 15.14 <0.001
Temporal cortex 118.04 ± 13.45 116.31 ± 14.46 115.25 ± 15.29 116.54 ± 13.97 <0.001
Hippocampus, total 6.89 ± 1.00 6.92 ± 0.99 6.92 ± 0.93 6.91 ± 0.94 0.716
Hippocampus, left 3.35 ± 0.49 3.38 ± 0.50 3.46 ± 0.47 3.40 ± 0.47 0.006
Hippocampus, right 3.54 ± 0.54 3.55 ± 0.51 3.45 ± 0.48∧• 3.51 ± 0.49 <0.001
Lateral ventricles 34.67 ± 12.13# 35.44 ± 12.91#• 34.55 ± 12.12 34.89 ± 11.96 <0.001

Actual volumes (Volumes, mL) computed by icobrain dm were reported as mean ± SD. Achieva: Philips Medical Systems Achieva dStream 1.5T. Ingenia: Philips Medical Systems Ingenia 3T. GE: GE Discovery MR750w 3T. p-value: Difference between the three scanner types. Post-hoc comparison: p-value < 0.005 between Achieva and GE. p-value < 0.005 between Ingenia and GE. #p-value < 0.005 between Achieva and Ingenia.