Table 4.

Two 2 × 2 contingency tables on antigen rapid test performance in the assessment of patients with COVID-19. The first table focuses on the rapid antigen test among symptomatic patients for SARS-CoV-2 and the table below focuses on the rapid antigen test among asymptomatic patients for SARS-CoV-2.

Patients COVID-19 non-infected Patients COVID-19 infected
Only considering symptomatic patients for COVID-19
Negative antigen test for COVID-19 876 30
Positive antigen test for COVID-19 21 264
Sensitivity 89.8% (88.0–91.5)
Specificity 97.6% (97.1–98.1)
Positive predictive value 92.6% (91.0–94.1)
Negative predictive value 96.7% (96.0–97.2)
Accuracy (correctly classified) 95.7% (95.1–96.3)



Only considering asymptomatic patients for COVID-19
Negative antigen test for COVID-19 2594 38
Positive antigen test for COVID-19 11 65
Sensitivity 63.1% (58.4–67.8)
Specificity 99.6% (99.5–99.7)
Positive predictive value 85.5% (81.5–89.5)
Negative predictive value 98.5% (98.3–98.7)
Accuracy (correctly classified) 98.2% (97.9–98.4)