Skip to main content
. 2021 Jun 17;109(6):605–614. doi: 10.1007/s00223-021-00874-9

Table 4.

18F-NaF PET’s diagnostic accuracy in ROD

Variables AUC Criterion Sensitivity (%) Specificity (%) NPV (%) PPV (%)
a. 18F-NaF PET strength to recognize high turnover/hyperparathyroid bone disease

 18F-fluoride activity in the PET scan

unified TMV-based

0.86 Cut-off > 0.055 Ml/min/Ml 82 100 88 100

 PTH

unified TMV-based

0.69  > 450 ng/ml 55 87 72 75
b. 18F-NaF PET strength to recognize low turnover/adynamic bone disease

 18F-fluoride activity in the PET scan

unified TMV-based

0.87 Cut-off < 0.038 Ml/min/Ml 100 70 100 50

 18F-fluoride activity in the PET scan

turnover -based

0.83 Cut-off < 0.038 Ml/min/Ml 63 80 57 83
 PTH—unified TMV-based 0.78  < 185 ng/ml 67 85 89 57
 PTH—turnover-based 0.68  < 185 ng/ml 31 80 42 71