Table 2.
PC 500 | PC 200 | KFAC 500 | KFAC 200 | |
---|---|---|---|---|
MVC max (Nm) | 269 (244, 294) | 265 (243, 288) | 262 (235, 289) | 262 (236, 288) |
Absolute torque max (Nm) | 171a (153, 188) | 122 (102, 142) | 172a (148, 197) | 144 (125, 163) |
Relative torque max (% MVC) | 71a (62, 79) | 56 (44, 67) | 72a (60, 84) | 65 (52, 77) |
Discomfort (0, 10) | 9.8 (9.5, 10.0) | 9.0 (8.4, 9.7) | 9.2 (8.7, 9.8) | 9.3 (8.9, 9.8) |
Intensity max (mA) | 128 (94, 175) | 155b (118, 193) | 131 (104, 159) | 150b (128, 188) |
Values are reported as mean (95% confidence interval). KFAC, kHz frequency alternating currents; NMES, neuromuscular electrical stimulation; MVC, maximal voluntary contraction; PC, pulsed current.
Phase durations of 500 µs produced greater absolute and evoked torque maximum than 200 µs.
Phase durations of 200 µs displayed higher values of intensity when compared 500 µs.