Skip to main content
. 2021 Aug 25;15(3):197–202. doi: 10.34172/joddd.2021.033

Table 2. The surface area of contamination regarding the positions and distances from the oral cavity.

Groups
HVE (% surface area)*
(n=5)
Mean ± SD
HVE+EOS (% surface area)*
(n=5)
Mean ± SD
Positions/
Distances
4 O’clock 6 O’clock 8 O’clock 4 O’clock 6 O’clock 8 O’clock
20 cm 1.237±0.251A 0.413±0.183B 0.343±0.238BC 0.842±0.102CD 0.163±0.079C 0.103±0.066EC
40 cm 0 0 0 0 0 0
60 cm 0 0 0 0 0 0

*Two-way ANOVA with multiple comparisons test, significant at the P < 0.05 level, the same letter in the superscript is not significantly different from another. EOS, extra-oral suction; HVE, high-volume evacuator.