Table 4.

Results of the tests carried out according to the current regulations for considering self-compacting concrete (EHE-08).

Test Measured Parameter Test Result Permissible Range (EHE-08)
SSC-Control Slump flow T50 (s) 2.8
df (mm) 690
J-Ring djf (mm) 650
L-Box Cb 0.78
V-funnel Tv (s) 5.02
SSC-20BBA-C Slump flow T50 (s) 1.5
df (mm) 650
J-Ring djf (mm) 650
L-Box Cb 0.75
V-funnel Tv (s) 4.6
SSC-40BBA-C Slump flow T50 (s) 1.6
df (mm) 660
J-Ring djf (mm) 670
L-Box Cb 0.78
V-funnel Tv (s) 5.9
SSC-60BBA-C Slump flow T50 (s) 2.1 T50 ≤ 8 s (s)
df (mm) 760 550 mm ≤ df ≤ 850 mm
J-Ring djf (mm) 740 ≥df-50 mm
L-Box Cb 0.75 0.75 ≤ Cb ≤ 1.00
V-funnel Tv (s) 7.9 4 s ≤ Tv ≤ 20 s
SSC-10BBA Slump flow T50 (s) 3.6
df (mm) 660
J-Ring djf (mm) 610
L-Box Cb 0.79
V-funnel Tv (s) 10
SSC-20BBA Slump flow T50 (s) 4
df (mm) 690
J-Ring djf (mm) 650
L-Box CbL 0.8
V-funnel Tv (s) 10
SSC-30BBA Slump flow T50 (s) 4.3
df (mm) 640
J-Ring djf (mm) 630
L-Box CbL 0.81
V-funnel Tv (s) 11