Table 4.

Equivalent plastic strain after final analysis step for different material configurations.

Configuration
(0-PLA; 1-PCL)
Equivalent Plastic Strain [mm/mm] Configuration
(0-PLA; 1-PCL)
Equivalent Plastic Strain [mm/mm]
0000 0.72 1000 0.74
0001 0.72 1001 0.72
0010 0.71 1010 0.72
0011 0.71 1011 0.68
0100 0.72 1100 0.73
0101 0.71 1101 0.69
0110 0.71 1110 0.71
0111 0.65 1111 0.61