Diagnostic performance of multi-b diffusion maps based on ME, BE, SE and DKI models

Maps AUC (95% CI) Sensitivity% (95% CI) Specificity% (95% CI) PPV% (95% CI) NPV% (95% CI)
ME
 ADC0–1000 0.83 (0.80–0.87) 88 (82–93) 79 (68–87) 87 (81–92) 80 (72–88)
 ADCall-b 0.84 (0.80–0.88) 88 (82–93) 81 (71–90) 88 (82–94) 80 (72–88)
BE-IVIM
 D 0.85 (0.81–0.89) 88 (81–93) 82 (73–90) 89 (83–93) 80 (72–89)
 D* 0.80 (0.74–0.83) 83 (76–88) 77 (66–86) 85 (77–91) 73 (65–81)
 f 0.82 (0.77–0.86) 85 (79–90) 79 (68–87) 86 (80–92) 77 (68–84)
SE
 DDC 0.81 (0.77–0.85) 85 (78–90) 77 (66–86) 85 (79–91) 76 (68–84)
 α 0.80 (0.77–0.84) 85 (79–89) 76 (67–86) 85 (80–91) 76 (69–82)
DKI
 D 0.83 (0.80–0.88) 87 (80–94) 79 (69–88) 87 (81–93) 80 (71–89)
 K 0.84 (0.80–0.88) 87 (80–92) 81 (72–89) 88 (83–93) 79 (72–86)

AUC area under the receiver operating characteristic curve, CI confidence interval, PPV positive predictive value, NPV negative predictive value