Skip to main content
. Author manuscript; available in PMC: 2022 Apr 1.
Published in final edited form as: Toxicol In Vitro. 2020 Dec 19;72:105070. doi: 10.1016/j.tiv.2020.105070

Table 2.

Overall Accuracy Comparison of the Same Chemicals between BCOP (LLBO), BCOP (OP-KIT), EpiOcular, ICE, Ocular Irritection, OptiSafe, and STE

Test Comparisons n False Negative
False Positive
Accuracy (%) Balanced Accuracy(%)
% (missed/total) Commonly Missed
% (missed/total) Commonly Missed
% (same/total) % (same/total)

BCOP (LLBO) 112 7.2 (6/83) 45.5 (5/11) 58.6 (17/29) 88.2 (15/17) 79.5 (89/112) 67.1
BCOP (OPKIT) 12.0 (10/83) 51.7 (15/29) 77.7 (87/112) 68.1

BCOP (LLBO) 104 6.3 (5/79) 0.0 (0/7) 48.0 (12/25) 38.5 (5/13) 83.7 (87/104) 72.8
EpiOcular 2.5 (2/79) 24.0 (6/25) 92.3 (96/104) 86.7

BCOP (LLBO) 37 7.1 (2/28) 0.0 (0/4) 66.7 (6/9) 50.0 (4/8) 78.4 (29/37) 63.1
ICE 7.1 (2/28) 66.7 (6/9) 78.4 (29/37) 63.1

BCOP (LLBO) 32 9.5 (2/21) 0.0 (0/3) 45.5 (5/11) 66.7 (4/6) 78.1 (25/32) 72.5
Ocular Irritection 4.8 (1/21) 45.5 (5/11) 81.3 (26/32) 74.9

BCOP (LLBO) 41 3.6 (1/28) 0.0 (0/1) 30.8 (4/13) 75.0 (3/4) 87.8 (36/41) 82.8
OptiSafe 0.0 (0/28) 23.1 (3/13) 92.7 (38/41) 88.5

BCOP (OP-KIT) 111 10.2 (9/88) 10.0 (1/10) 47.8 (11/23) 63.6 (7/11) 82.0 (91/111) 71.0
EpiOcular 2.3 (2/88) 30.4 (7/23) 91.9 (102/111) 83.6

BCOP (OP-KIT) 61 6.8 (3/44) 0.0 (0/5) 64.7 (11/17) 66.7 (10/15) 77.0 (47/61) 64.2
ICE 4.5 (2/44) 82.4 (14/17) 73.8 (45/61) 56.6

BCOP (OP-KIT) 44 9.1 (3/33) 0.0 (0/5) 45.5 (5/11) 66.7 (4/6) 81.8 (36/44) 72.7
Ocular Irritection 6.1 (2/33) 45.5 (5/11) 84.1 (37/44) 74.2

BCOP (OP-KIT) 43 8.8 (3/34) 0.0 (0/3) 33.3 (3/9) 100.0 (3/3) 86.0 (37/43) 78.9
OptiSafe 0.0 (0/34) 33.3 (3/9) 93.0 (40/43) 83.3

EpiOcular 43 2.9 (1/34) 50.0 (1/2) 44.4 (4/9) 42.9 (3/7) 88.4 (38/43) 76.3
ICE 5.9 (2/34) 66.7 (6/9) 81.4 (35/43) 63.7

EpiOcular 58 3.3 (1/30) 0.0 (0/3) 35.7 (10/28) 90.9 (10/11) 81.0 (47/58) 80.5
Ocular Irritection 6.7 (2/30) 39.3 (11/28) 77.6 (45/58) 77.0

EpiOcular 56 2.9 (1/35) 0.0 (0/1) 33.3 (7/21) 55.6 (5/9) 85.7 (48/56) 81.9
OptiSafe 0.0 (0/35) 33.3 (7/21) 87.5 (49/56) 83.3

ICE 28 4.8 (1/21) 0.0 (0/1) 100.0 (7/7) 42.9 (3/7) 71.4 (20/28) 47.6
Ocular Irritection 0.0 (0/21) 42.9 (3/7) 89.3 (25/28) 78.6

ICE 24 10.0 (2/20) 0.0 (0/2) 75.0 (3/4) 66.7 (2/3) 79.2 (19/24) 57.5
OptiSafe 0.0 (0/20) 50.0 (2/4) 91.7 (22/24) 75.0

Ocular Irritection 46 8.7 (2/23) 0.0 (0/2) 47.8 (11/23) 61.5 (8/13) 71.7 (33/46) 71.7
OptiSafe 0.0 (0/23) 43.5 (10/23) 78.3 (36/46) 78.3

STE 69 *20.8 (10/48) 10.0 (1/10) *0.0 (0/21) 0.0 (0/9) 85.5 (59/69) 89.6
BCOP (LLBO) *2.1 (1/47) *40.9 (9/22) 85.5 (59/69) 78.5

STE 84 *19.7 (12/61) 14.3 (2/14) *17.4 (4/23) 23.1 (3/13) 81.0 (68/84) 81.5
BCOP (OP-KIT) *6.7 (4/60) *50.0 (12/24) 81.0 (68/84) 71.7

STE 80 23.5 (12/51) 7.7 (1/13) 10.3 (3/29) 18.2 (2/11) 81.3 (65/80) 83.1
EpiOcular 3.9 (2/51) 34.5 (10/29) 85.0 (68/80) 80.8

STE 41 25.0 (7/28) 14.3 (1/7) 15.4 (2/13) 22.2 (2/9) 78.0 (32/41) 79.8
ICE 3.6 (1/28) 69.2 (9/13) 75.6 (31/41) 63.6

STE 40 33.3 (7/21) 0.0 (0/7) 10.5 (2/19) 11.1 (1/9) 77.5 (31/40) 78.1
Ocular Irritection 0.0 (0/21) 42.1 (8/19) 80.0 (32/40) 78.9

STE 56 31.0 (9/29) 0.0 (0/9) 7.4 (2/27) 28.6 (2/7) 80.4 (45/56) 80.8
OptiSafe 0.0 (0/29) 25.9 (7/27) 87.5 (49/56) 87.0

Table 2. Overall accuracy comparison of chemicals in common.

n is the number of chemicals in common between the test methods compared.

False negative (FN) is the number of positives misclassified as negatives [((FN) / (FN + TP)) • 100].

False positive (FP) is the number of negatives misclassified as positives [((FP) / (FP + TN)) • 100].

% (Missed/total) is the misclassification rate for chemicals in common. Commonly missed is the percent overlapping FNs or FPs.

Accuracy is the total correct predictions divided by the n in common. [((TP + TN) / (TP + TN + FP + FN)) • 100].

Balanced accuracy equally weights positives and negatives [((Sensitivity + Specificity) / 2) • 100].

BCOP = Bovine Corneal Opacity and Permeability; LLBO = Laser Light-Based Opacitometer; ICE = Isolated Chicken Eye; STE = Short Time Exposure. TP = True Positive; TN = True Negative; Sensitivity = [(TP) / (TP + FN)]; Specificity = [(TN) / (TN + FP)].

*

= has differing total FN and FP values in common due to differing in vivo classification of cetylpyridinium bromide. The in vivo classification of cetylpyridinium bromide for LLBO and OP-KIT was not classified (NC) and the classification for STE was category 1.