Published in final edited form as: Toxicol In Vitro. 2020 Dec 19;72:105070. doi: 10.1016/j.tiv.2020.105070

Table 3.

Published Accuracy Compared to Relative Accuracy

Test Method Published Accuracy Relative Accuracy Published FP rate Relative FP rate Published FN rate Relative FN rate Reference for Published
BCOP (LLBO) 83% 78.1 – 87.8% 45% 30.8 – 66.7% 6% 2.1 – 9.5% OECD, 2020a
BCOP (OP-KIT) 69% 77.0 – 86.0% 69% 33.3 – 64.7% 0% 6.7 – 12.0% OECD, 2020a
EpiOcular 80% 81.0 – 92.2% 37% 24.0 – 44.4% 4% 2.3 – 3.9% OECD, 2019a
ICE 88% 71.4 – 81.4% 24% 66.7 –100.0% 3% 3.6 – 10.0% OECD, 2018
OI 75% 71.7 – 89.3% 41% 39.3 – 47.8% 9% 0.0 – 8.7% OECD, 2019b
OS 79–80% 78.3 – 93.0% 40% 23.1 – 50.0% 0% 0.0 – 0.0% Choksi et al., 2020
STE 85% 77.5 – 85.5% 19% 0.0 – 17.4% 12% 19.7 – 33.3% OECD, 2020b

Table 3. Comparison of published statistics versus relative statistics. BCOP = Bovine Corneal Opacity & Permeability; LLBO = Laser Light-Based Opacitometer; ICE = Isolated Chicken Eye; OI = Ocular Irritection; OS = OptiSafe; STE = Short Time Exposure; FP = false positive; FN = false negative.