TABLE VII. Accuracy (%) of COVID-19 Classification Network With Different Self-Supervised Weights.
| Precision | Recall | F1 | |
|---|---|---|---|
| Train-from-scratch | 81.5 | 88.0 | 84.6 |
| Rubik's cube [12] | 86.0 | 86.0 | 86.0 |
| Rubik's cube Pro | 89.6 | 86.0 | 87.8 |
| Precision | Recall | F1 | |
|---|---|---|---|
| Train-from-scratch | 81.5 | 88.0 | 84.6 |
| Rubik's cube [12] | 86.0 | 86.0 | 86.0 |