Skip to main content
. 2021 Oct 12;9(10):e32301. doi: 10.2196/32301

Table 3.

Automated transcription and documentation performance by different settings.

Setting ASRa transcription output Automated TCCCb documentation

Medical word error rate (%) P valuec Precision Recall F1 score
Setting 1: baseline 69.9 N/Ad 0.484 0.828 0.611
Setting 2: baseline + multi-style training 43.0 Setting 1 vs 2: <.001 0.634 0.824 0.717
Setting 3: baseline + multi-style training + updated language model 33.3 Setting 2 vs 3: <.001 0.803 0.824 0.813
Setting 4: baseline + multi-style training + updated language model + speech enhancement 46.3 Setting 3 vs 4: <.001 0.747 0.819 0.781

aASR: automatic speech recognition.

bTCCC: Tactical Combat Casualty Care.

cMcNemar test with Bonferroni correction was used to calculate the statistical significance.

dN/A: not applicable.