Skip to main content
. 2021 Sep 9;81(9):800. doi: 10.1140/epjc/s10052-021-09538-2

Table 3.

Summary of the BCID-averaged corrections to σvis (in %) obtained with the vdM scan calibrations at s=13TeV in 2015 and 2016. When a range is shown, it is because of possible scan-to-scan variations. To obtain the impact on σvis, each correction is consecutively included, the fits are redone following the order below, and the result is compared with the baseline. The impact from transverse factorizability is obtained separately (as discussed in Sect. 4.4)

Source Impact on σvis (%)
2015 2016
Ghost and satellite charge +0.2 +0.3
Orbit drift +0.6 to +1.0 +0.2 to +1.0
Residual beam position corrections -0.6 to +0.4 -0.5 to -0.2
Beam-beam effects +0.6 +0.4
Length scale calibration −0.4 −1.3
Transverse factorizability +0.8 to +1.3 +0.6