Skip to main content
. 2021 Oct 13;88:106492. doi: 10.1016/j.ijscr.2021.106492

Table 3.

Number of true positive, false positive, true negative, false-negative cases, sensitivity, specificity, accuracy and Diagnostic odds ratio for medial meniscal tears.

Medial meniscal tears
TP FP TN FN Sensitivitya Specificitya Accuracya DOR (p)
Joint line tenderness 14 14 16 6 70%
(49.9 - 90)
53.3%
(35.5–71.2)
60%
(46.42 -73.58)
2.6667
(0.1078)
McMurray's test 16 8 22 4 80%
(62.5–97.7)
73.3%
(57.5–89.2)
76%
(64.16–87.84)
11.2000
(0.0006)
Apley's test 13 9 21 7 65%
(44.1–85.9)
70%
(53.6–86.4)
68%
(55.07–80.93)
4.3333
(0.0172)
Thessaly test 14 7 23 6 70%
(49.9–90.1)
76.7%
(61.5–91.8)
74%
(61.84–86.16)
7.6667
(0.0018)
Composite test 17 8 22 3 85%
(69.4 - 100)
73.3%
(57.5–89.2)
78.0%
(66.52–89.48)
15.5833
(0.0003)
MRI scans 18 5 25 2 90%
(76.9 - 100)
83.3%
(70–96.7)
86%
(76.83–95.62)
45.000
(<0.0001)
a