Skip to main content
. 2021 Aug 4;9(1):10.1128/spectrum.00342-21. doi: 10.1128/spectrum.00342-21

TABLE 5.

INDICAID COVID-19 rapid antigen test performance during implementation in outbreak screening centers in Hong Kong

No. INDICAID COVID-19 rapid antigen test samples No. comparative method (RT-PCR) samples
Positive Negative Total
Positive 32 18 50
Negative 6 22,938 22,944
Total 38 22,956 22,994