Skip to main content
. Author manuscript; available in PMC: 2021 Oct 29.
Published in final edited form as: J Trauma Acute Care Surg. 2020 May;88(5):607–614. doi: 10.1097/TA.0000000000002598

TABLE 3.

Comparison of Automated Versus Manual Characterization of Treatment Appropriateness

Manual
None Indicated Missed Nonindicated Total Precision Recall
Airway
System  None 109 0 0 0 109 1 0.94
 Indicated 0 15 0 0 15 1 0.83
 Missed 7 3 7 0 17 0.41 1
 Nonindicated 0 0 0 1 1 1 1
 Total 116 18 7 1 142
System IV access
 Indicated 133 2 135 0.99 1
 Missed 0 7 7 1 0.78
 Total 133 9 142
IO access
System  None 130 0 1 0 131 0.99 0.99
 Indicated 0 5 0 0 5 1 0.83
 Missed 1 1 1 0 3 0.33 0.5
 Nonindicated 0 0 0 3 3 1 1
 Total 131 6 2 3 142
Needle decompression
System  None 133 0 0 1 134 0.99 1
 Indicated 0 1 0 0 1 1 1
 Missed 0 0 7 0 7 1 1
 Total 133 1 7 1 142
TXA
System  None 120 0 1 0 121 0.99 0.97
 Indicated 0 8 0 0 8 1 0.8
 Missed 3 0 5 0 8 0.63 0.83
 Nonindicated 1 2 0 2 5 0.4 1
 Total 124 10 6 2 142
PRBCs
System  None 124 0 1 125 0.99 0.98
 Indicated 0 8 0 8 1 0.89
 Missed 3 0 5 8 0.63 0.83
 Nonindicated 0 1 0 1
 Total 127 9 6 142
Cystalloid bolus
System  None 107 0 0 4 111 0.96 0.96
 Indicated 0 2 0 0 2 1 0.5
 Missed 3 0 5 0 8 0.63 1
 Nonindicated 1 2 0 18 21 0.86 0.82
 Total 111 4 5 22 142
Chest compression
System  None 136 0 0 136 1 0.99
 Indicated 0 3 0 3 1 1
 Missed 1 0 2 3 0.67 1
 Total 137 3 2 142